{"title":"Euchner","description":"","products":[{"product_id":"ctp-l1-ar-u-ha-az-sh-123362","title":"Euchner transponder-coded safety switch CTP-L1-AR-U-HA-AZ-SH-123362","description":"\u003cp\u003eWork area\u003cbr\u003eRepeatability R according to \u003cbr\u003eEN 60947-5-2: 10%\u003cbr\u003e\u003cbr\u003eElectrical connection values\u003cbr\u003eExternal protection \u003cbr\u003e(Operating voltage U_B): 0.25 ... 8 A\u003cbr\u003eExternal fuse protection (magnetic operating voltage IMP): 0.5 ... 8 A\u003cbr\u003eConnected power: 6 W\u003cbr\u003eRated insulation voltage U_i: 50 V\u003cbr\u003eRated impulse withstand voltage U_imp: 0.5 kV\u003cbr\u003eOperating voltage DC U: 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple \u003c 5%, PELV\u003cbr\u003eEMC protection requirements: in accordance with \u003cbr\u003eEN IEC 60947-5-3\u003cbr\u003eUsage category DC-13: 24V 150mA\u003cbr\u003eMagnet operating voltage DC U_IMP: 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple \u003c 5%, PELV\u003cbr\u003eMagnet duty cycle ED: 100%\u003cbr\u003eRisk time according to EN 60947-5-3: max. 260 ms\u003cbr\u003eRisk time according to EN 60947-5-3, extension for each additional device: \u003cbr\u003emax. 5 ms\u003cbr\u003eSwitching load according to UL: 24V DC, Class 2\u003cbr\u003eProtection class EN IEC 61140: III\u003cbr\u003eCurrent consumption I_UB: 40 mA\u003cbr\u003eCurrent consumption I_IMP: 400 mA\u003cbr\u003eTest pulse duration: max. 1.0 ms\u003cbr\u003eTest pulse interval: min. 140 ms\u003cbr\u003ePollution level \u003cbr\u003e(external, according to EN 60947-1): 3\u003cbr\u003eSignal output OD, OI, OL\u003cbr\u003eType of output: p-switching, short-circuit proof\u003cbr\u003eOutput voltage: 0.8xUB...UB V DC\u003cbr\u003eSwitching current: 1...50 mA\u003cbr\u003eSafety outputs FO1A \/ FO1B\u003cbr\u003eType of output: 2 semiconductor outputs, p-switching, short-circuit proof\u003cbr\u003eOutput voltage \u003cbr\u003eLOW U(FO1A) \/ U(FO1B): 0 ... 1 V DC\u003cbr\u003eHIGH U(FO1A) \/ U(FO1B): UB-1.5 ... UB V DC\u003cbr\u003eDiscrepancy time for both safety outputs: max. 10 ms according to EN IEC 60947-5-3\u003cbr\u003eSwitch-on time: max. 400 ms\u003cbr\u003eResidual current I_r: max. 0.25 mA\u003cbr\u003eSwitching current per safety output \u003cbr\u003eFO1A \/ FO1B: 1 ... 150 mA\u003cbr\u003e\u003cbr\u003eMechanical values and environment\u003cbr\u003eApproach speed: max. 20 m\/min\u003cbr\u003eConnection type: 1 M23 connector, \u003cbr\u003e19 pin, RC18\u003cbr\u003ePull-out force: 20 N\u003cbr\u003eReadiness delay: 8 s\u003cbr\u003eActuation force: 10 N\u003cbr\u003eInstallation position: any\u003cbr\u003eSwitching frequency: max. 0.5 Hz\u003cbr\u003eMechanical life: 1 x 10⁶\u003cbr\u003eCaster: 5 mm\u003cbr\u003eRetention force: 20 N\u003cbr\u003eShock and vibration resistance: according \u003cbr\u003eEN IEC 60947-5-3\u003cbr\u003eProtection class: IP67\u003cbr\u003eambient temperature \u003cbr\u003eU_B = 24V DC: -20 ... +55 °C\u003cbr\u003ematerial\u003cbr\u003eSwitch head cover: die-cast zinc\u003cbr\u003eSafety switch housing: glass fiber reinforced thermoplastic\u003cbr\u003eLocking force F_max: 3900 N\u003cbr\u003eLocking force F_Zh: 3000 N\u003cbr\u003eGuard locking principle: closed-circuit principle\u003c\/p\u003e","brand":"Euchner","offers":[{"title":"Default Title","offer_id":47394300821849,"sku":"","price":289.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0780\/1434\/9657\/files\/CTP-L1-AR-U-HA-AZ-SH-123362_2.jpg?v=1704550868"},{"product_id":"ces-i-ap-u-c04-usi-115150","title":"Euchner non-contact safety switch CES-I-AP-U-C04-USI-115150","description":"Operating range\u003cbr\u003eRepeat accuracy R according to EN 60947-5-2: \u003c= 10\u003cbr\u003e\u003cbr\u003eElectrical connection values\u003cbr\u003eExternal fuse protection (operating voltage): 0.25 ... 8 A\u003cbr\u003eRated insulation voltage Ui: 300 V\u003cbr\u003eRated impulse withstand voltage Uimp: 1.5 kV\u003cbr\u003eOperating voltage DC UB: 24 V DC -15% ... +15% regulated, ripple \u003c 5 %, PELV\u003cbr\u003eSwitch-on time of safety outputs: max. 300 ms\u003cbr\u003eEMC protection requirements: in accordance with EN IEC 60947-5-3\u003cbr\u003eRisk time in accordance with EN 60947-5-3: max. 260 ms\u003cbr\u003eProtection class: III\u003cbr\u003eCurrent consumption with unloaded outputs: max. 35 mA\u003cbr\u003eDegree of contamination (external, in accordance with EN 60947-1): 3\u003cbr\u003eSafety outputs FO1A \/ FO1B\u003cbr\u003eType of output: semiconductor outputs, p-switching, short-circuit-proof\u003cbr\u003eOutput voltage LOW U(FO1A) \/ U(FO1B): 0 ... 1 V DC\u003cbr\u003eOutput voltage HIGH U(FO1A) \/ U(FO1B): UB-1.5V ... UB V DC\u003cbr\u003eConditional rated short-circuit current: 100 A\u003cbr\u003eDiscrepancy time: max. 10 ms\u003cbr\u003eUtilization category DC-13: 24V 150mA\u003cbr\u003eResidual current Ir: max. 0.25 mA\u003cbr\u003eSwitching current per safety output: 1 ... 150 mA\u003cbr\u003eTest pulse duration: max. 0.3 ms\u003cbr\u003eTest pulse interval: min. 100 ms\u003cbr\u003e\u003cbr\u003eMechanical values and environment\u003cbr\u003eConnection type: PUR cable 100mm with plug connector M12x1, 5-pin, Pin5 not assigned\u003cbr\u003eTightening torque of fastening screws: max. 0.8 Nm\u003cbr\u003eReady delay: 0.5 s\u003cbr\u003eDynamic bending radius: 10 x cable diameter\u003cbr\u003eStatic bending radius: 5 x cable diameter\u003cbr\u003eInstallation position: any\u003cbr\u003eSwitching frequency: max. 1 Hz\u003cbr\u003eMounting distance between 2 switches or 2 actuators: min. 80 mm\u003cbr\u003eMounting type: Not flush on metal\u003cbr\u003eShock and vibration resistance: in accordance with EN IEC 60947-5-3\u003cbr\u003eProtection class: IP67\u003cbr\u003eAmbient temperature cable (dynamic): -25 ... +65 °C\u003cbr\u003eAmbient temperature cable (static): -25 ... +65 °C\u003cbr\u003e\u003cbr\u003eMaterial\u003cbr\u003eRubber base: NBR 80 ±5 Shore\u003cbr\u003eHousing: Plastic, PBT","brand":"Euchner","offers":[{"title":"Default Title","offer_id":47394304000345,"sku":"","price":139.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0780\/1434\/9657\/files\/CES-I-AP-U-C04-USI-115150_1.jpg?v=1704550904"},{"product_id":"ces-ap-c01-ah-sb-111145","title":"Euchner non-contact safety switch CES-AP-C01-AH-SB-111145","description":"Operating range\u003cbr data-mce-fragment=\"1\"\u003eRepeat accuracy R according to EN 60947-5-2: \u003c= 10\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eElectrical connection values\u003cbr data-mce-fragment=\"1\"\u003eExternal fuse protection (operating voltage): 0.25 ... 8 A\u003cbr data-mce-fragment=\"1\"\u003eRated insulation voltage Ui: 300 V\u003cbr data-mce-fragment=\"1\"\u003eRated impulse withstand voltage Uimp: 1.5 kV\u003cbr data-mce-fragment=\"1\"\u003eOperating voltage DC UB: 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple \u003c 5 %, PELV\u003cbr data-mce-fragment=\"1\"\u003eSwitch-on time of safety outputs: max. 400 ms\u003cbr data-mce-fragment=\"1\"\u003eEMC protection requirements: in accordance with EN IEC 60947-5-3\u003cbr data-mce-fragment=\"1\"\u003eRisk time in accordance with EN 60947-5-3: max. 260 ms\u003cbr data-mce-fragment=\"1\"\u003eProtection class: III\u003cbr data-mce-fragment=\"1\"\u003eCurrent consumption with unloaded outputs: max. 50 mA\u003cbr data-mce-fragment=\"1\"\u003eDegree of contamination (external, in accordance with EN 60947-1): 3\u003cbr data-mce-fragment=\"1\"\u003eSafety outputs OA \/ OB \u003cbr data-mce-fragment=\"1\"\u003eType of output: semiconductor outputs, p-switching, short-circuit-proof\u003cbr data-mce-fragment=\"1\"\u003eOutput voltage: HIGH U (OA, OB): UB-1.5 ... UB V DC\u003cbr data-mce-fragment=\"1\"\u003eLOW U (OA, OB): 0 ... 1 V DC\u003cbr data-mce-fragment=\"1\"\u003eConditional rated short-circuit current: max. 100 A\u003cbr data-mce-fragment=\"1\"\u003eDiscrepancy time: max. 10 ms\u003cbr data-mce-fragment=\"1\"\u003eUtilization category DC-13: 24V 400mA\u003cbr data-mce-fragment=\"1\"\u003eResidual current Ir: max. 0.25 mA\u003cbr data-mce-fragment=\"1\"\u003eSwitching current per safety output: 1 ... 400 mA\u003cbr data-mce-fragment=\"1\"\u003eTest pulse duration: max. 0.4 ms\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eMechanical values and environment\u003cbr data-mce-fragment=\"1\"\u003eConnection type: M12 plug connector, 5-pin, pin 5 not assigned\u003cbr data-mce-fragment=\"1\"\u003eTightening torque of fastening screws: max. 1 Nm\u003cbr data-mce-fragment=\"1\"\u003eReady delay: 0.5 s\u003cbr data-mce-fragment=\"1\"\u003eInstallation position: any\u003cbr data-mce-fragment=\"1\"\u003eSwitching frequency: max. 1 Hz\u003cbr data-mce-fragment=\"1\"\u003eMounting distance: min. 40 mm\u003cbr data-mce-fragment=\"1\"\u003eShock and vibration resistance: in accordance with EN IEC 60947-5-3\u003cbr data-mce-fragment=\"1\"\u003eProtection class: IP67\u003cbr data-mce-fragment=\"1\"\u003eAmbient temperature: -20 ... +55 °C\u003cbr data-mce-fragment=\"1\"\u003eHousing material: plastic, PBT\u003cbr data-mce-fragment=\"1\"\u003e","brand":"Euchner","offers":[{"title":"Default Title","offer_id":47394304885081,"sku":"","price":169.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0780\/1434\/9657\/files\/CES-AP-C01-AH-SB-111145_1.jpg?v=1704550947"},{"product_id":"mgb-e-a2-106051","title":"Euchner escape release module MGB-E-A2-106051","description":"\u003cp\u003eMechanical values and environment\u003cbr\u003eInstallation position: any\u003cbr\u003eMechanical service life: 1 x 10⁶\u003cbr\u003eAmbient temperature: -30 ... +55 °C\u003cbr\u003eHousing material: die-cast zinc \/ powder-coated stainless steel\u003cbr\u003e\u003cbr\u003eMiscellaneous\u003cbr\u003eProduct version number: V2.0.0\u003cbr\u003eAdditional feature: with mounting plate\u003c\/p\u003e","brand":"Euchner","offers":[{"title":"Default Title","offer_id":47394748563801,"sku":"","price":109.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0780\/1434\/9657\/files\/MGB-E-A2-106051_3.jpg?v=1704550311"},{"product_id":"mgb-h-aa-1a2-l-106221","title":"Euchner handle module MGB-H-AA1A2-L-106221","description":"Mechanical values and environment\u003cbr\u003eInstallation position: DIN left door hinge\u003cbr\u003eProtection class: IP65\u003cbr\u003eAmbient temperature: -20 ... +55 °C\u003cbr\u003eHousing material: Glass fiber reinforced plastic, zinc die-cast, nickel-plated, stainless steel\u003cbr\u003e\u003cbr\u003eMiscellaneous\u003cbr\u003eProduct version number: V3.0.0\u003cbr\u003eAdditional feature: with mounting plate","brand":"Euchner","offers":[{"title":"Default Title","offer_id":47394748957017,"sku":"","price":149.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0780\/1434\/9657\/files\/MGB-H-AA-1A2-L-106221_2.jpg?v=1704550159"},{"product_id":"mgb-h-aa-1a2-r-106049","title":"Euchner handle module MGB-H-AA1A2-R-106049","description":"Mechanical values and environment\u003cbr\u003eInstallation position: DIN right door hinge\u003cbr\u003eProtection class: IP65\u003cbr\u003eAmbient temperature: -20 ... +55 °C\u003cbr\u003eHousing material: Glass fiber reinforced plastic, zinc die-cast, nickel-plated, stainless steel\u003cbr\u003e\u003cbr\u003eMiscellaneous\u003cbr\u003eProduct version number: V3.0.0\u003cbr\u003eAdditional feature: with mounting plate","brand":"Euchner","offers":[{"title":"Default Title","offer_id":47394749579609,"sku":"","price":199.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0780\/1434\/9657\/files\/MGB-H-AA-1A2-R-106049_2.jpg?v=1704550110"},{"product_id":"mgb-l1b-pna-l-121861","title":"Euchner evaluation module and bus module MGB-L1B-PNA-L-121861","description":"\u003cp\u003eWork area\u003cbr\u003eSecure switch-off distance s Door position: max. 65 mm\u003cbr\u003e\u003cbr\u003eElectrical connection values\u003cbr\u003eEthernet connection cable: Profinet I\/O cable, at least Cat. 5e\u003cbr\u003eRated insulation voltage Ui: 75 V\u003cbr\u003eRated impulse withstand voltage Uimp: 0.5 kV\u003cbr\u003eEMC protection requirements: According to EN 61000-4 and EN 61326-3-1\u003cbr\u003eMaximum feed current in connection block X1, X2: max. 4000 mA\u003cbr\u003eProtection class: III\u003cbr\u003eCurrent consumption: max. 500 mA\u003cbr\u003eTransponder coding: Unicode\u003cbr\u003eDegree of contamination (external, according to EN 60947-1): 3\u003cbr\u003ePower supply X1\u003cbr\u003eExternal fuse: min. 1 A slow\u003cbr\u003eOperating voltage DC L1: 24 V DC -15% ... +10%\u003cbr\u003eAuxiliary voltage DC L2: 24 V DC -15% ... +10%\u003cbr\u003ePower supply X2\u003cbr\u003eOperating voltage DC L1: 24 V DC -15% ... +10%\u003cbr\u003eAuxiliary voltage DC L2: 24 V DC -15% ... +10%\u003cbr\u003e\u003cbr\u003eMechanical values and environment\u003cbr\u003eConnection type according to IEC 61076-2-101, Profinet I\/O cable, at least Cat. 5e: 7\/8\" Power M12 D-coded, shielded\u003cbr\u003eInstallation position: door hinge DIN left\u003cbr\u003eSwitching frequency: 0.25 Hz\u003cbr\u003eResponse time\u003cbr\u003eDoor position: max. 550 ms switch-off time\u003cbr\u003eEmergency stop \/ machine stop: max. 250 ms switch-off time\u003cbr\u003eBolt position: max. 550 ms switch-off time\u003cbr\u003eGuard locking: max. 550 ms switch-off time\u003cbr\u003eShock and vibration resistance: according to EN IEC 60947-5-3\u003cbr\u003eProtection class: IP54\u003cbr\u003eAmbient temperature at U = 24V DC: -20 ... +55 °C\u003cbr\u003eHousing material: glass fiber reinforced plastic, die-cast zinc, nickel-plated, stainless steel\u003cbr\u003eLocking force F: 2000 N\u003cbr\u003eGuard locking principle: closed-circuit principle\u003c\/p\u003e","brand":"Euchner","offers":[{"title":"Default Title","offer_id":47394750431577,"sku":"","price":699.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0780\/1434\/9657\/files\/MGB-L1B-PNA-L-121861_3.jpg?v=1704550051"},{"product_id":"mgb-l1b-pna-r-121857","title":"Euchner evaluation module and bus module MGB-L1B-PNA-R-121857","description":"\u003cp\u003eOperating range\u003cbr data-mce-fragment=\"1\"\u003eSecured switch-off distance s Door position: max. 65 mm\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eElectrical connection values\u003cbr data-mce-fragment=\"1\"\u003eEthernet connection cable: Profinet I\/O cable, \u003cbr data-mce-fragment=\"1\"\u003emin. Cat. 5e\u003cbr data-mce-fragment=\"1\"\u003eRated insulation voltage Ui: 75 V\u003cbr data-mce-fragment=\"1\"\u003eRated impulse withstand voltage Uimp: 0.5 kV\u003cbr data-mce-fragment=\"1\"\u003eEMC protection requirements: In accordance with EN 61000-4 and \u003cbr data-mce-fragment=\"1\"\u003eEN 61326-3-1\u003cbr data-mce-fragment=\"1\"\u003eMaximum supply current in terminal block X1, X2: \u003cbr data-mce-fragment=\"1\"\u003emax. 4000 mA\u003cbr data-mce-fragment=\"1\"\u003eProtection class: III\u003cbr data-mce-fragment=\"1\"\u003eCurrent consumption: max. 500 mA\u003cbr data-mce-fragment=\"1\"\u003eTransponder coding: Unicode\u003cbr data-mce-fragment=\"1\"\u003eDegree of contamination (external, in accordance with EN 60947-1): 3\u003cbr data-mce-fragment=\"1\"\u003ePower supply X1\u003cbr data-mce-fragment=\"1\"\u003eExternal fuse protection: min. 1 A slow-blow\u003cbr data-mce-fragment=\"1\"\u003eOperating voltage DC L1: 24 V DC -15% ... +10%\u003cbr data-mce-fragment=\"1\"\u003eAuxiliary voltage DC L2: 24 V DC -15% ... +10%\u003cbr data-mce-fragment=\"1\"\u003ePower supply X2\u003cbr data-mce-fragment=\"1\"\u003eOperating voltage DC L1: 24 V DC -15% ... +10%\u003cbr data-mce-fragment=\"1\"\u003eAuxiliary voltage DC L2: 24 V DC -15% ... +10%\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eMechanical values and environment\u003cbr data-mce-fragment=\"1\"\u003eConnection type to IEC 61076-2-101, Profinet I\/O cable, min. Cat. 5e: 7\/8\" Power M12 D-coded, shielded\u003cbr data-mce-fragment=\"1\"\u003eInstallation position: door hinge DIN right\u003cbr data-mce-fragment=\"1\"\u003eSwitching frequency: 0.25 Hz\u003cbr data-mce-fragment=\"1\"\u003eResponse time\u003cbr data-mce-fragment=\"1\"\u003eDoor position: max. 550 ms switch-off time\u003cbr data-mce-fragment=\"1\"\u003eEmergency stop \/ machine stop: max. 250 ms switch-off time\u003cbr data-mce-fragment=\"1\"\u003eBolt position: max. 550 ms switch-off time\u003cbr data-mce-fragment=\"1\"\u003eGuard locking: max. 550 ms switch-off time\u003cbr data-mce-fragment=\"1\"\u003eShock and vibration resistance: in accordance with EN IEC 60947-5-3\u003cbr data-mce-fragment=\"1\"\u003eProtection class: IP54\u003cbr data-mce-fragment=\"1\"\u003eAmbient temperature at U = 24V DC: -20 ... +55 °C\u003cbr data-mce-fragment=\"1\"\u003eHousing material: glass fiber reinforced plastic, zinc die-cast, nickel-plated, stainless steel\u003cbr data-mce-fragment=\"1\"\u003eLocking force F: 2000 N\u003cbr data-mce-fragment=\"1\"\u003eLocking principle: closed-circuit current principle\u003cbr\u003e\u003c\/p\u003e","brand":"Euchner","offers":[{"title":"Default Title","offer_id":47394750693721,"sku":"","price":699.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0780\/1434\/9657\/files\/MGB-L1B-PNA-R-121857_3.jpg?v=1704549976"},{"product_id":"cem-m2-c60-pz-se-161320","title":"Euchner CEM-M2-C60-PZ-SE-161320 CEM-M2 magnetic locking","description":"\u003cp\u003eVariable magnetic locking CEM-C60 with permanent magnet, connector on the left; Magnetic locking for process protection; Locking magnet with locking force of 650 N; Function extension for safety switch CES-C04 \/ CES-C07; Flexibility through a large selection of safety switches; Highest safety level PL e \/ Category 4 for detecting the door position in combination with CES-C04 \/ CES-C07; Transponder coding enables high protection against manipulation; Simple connection of the electromagnet via M12 connector, 5-pin; Yellow LED to display voltage on the magnet; Nickel-plated magnet surface with high corrosion resistance; Integrated permanent magnet, 30 N locking force\u003c\/p\u003e","brand":"Euchner","offers":[{"title":"Default Title","offer_id":48304754983257,"sku":null,"price":299.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0780\/1434\/9657\/files\/IMG_8616.jpg?v=1715101936"},{"product_id":"ces-a-bba-071840","title":"Euchner CES-A-BBA-071840 CES-A actuator","description":"\u003cp\u003e Distance s Actuator: Not specified\u003cbr\u003e Minimum distance for lateral approach direction: min. 4 mm\u003cbr\u003e Switch-on distance at center offset m=0: 18 mm\u003cbr\u003e Assured switch-off distance sar with center offset m=0: max. 45 mm\u003cbr\u003e Assured switching distance sao at center offset m=0: min. 15 mm\u003cbr\u003e Switching hysteresis at center offset m=0: 1 ... 3 mm\u003cbr\u003e Electrical connection values:\u003cbr\u003e Power supply: inductive via reading head\u003cbr\u003e Mechanical values ​​and environment:\u003cbr\u003e Tightening torque of fastening screws: max. 1 Nm\u003cbr\u003e Installation position: active surface opposite reading head\u003cbr\u003e Protection class: IP65\/IP67\/IP69\/IP69K\u003cbr\u003e Ambient temperature: -25 ... +70 °C\u003cbr\u003e Material: Housing: Plastic (PPS)\u003c\/p\u003e","brand":"Euchner","offers":[{"title":"Default Title","offer_id":48304755016025,"sku":null,"price":99.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0780\/1434\/9657\/files\/IMG_8612.jpg?v=1715102384"},{"product_id":"ces-a-bbn-c04-115271","title":"Euchner CES-A-BBN-C04-115271 CES-A actuator","description":"\u003cp\u003e Electrical connection values: \u003cbr\u003ePower supply: inductive via reading head\u003cbr\u003e Mechanical values ​​and environment:\u003cbr\u003e Tightening torque of fastening screws: max. 0.8 Nm\u003cbr\u003e Installation position: active surface opposite reading head\u003cbr\u003e Protection class: IP67\/IP69K\u003cbr\u003e Ambient temperature: -25 ... +65 °C\u003cbr\u003e Material:\u003cbr\u003e Housing: plastic (PBT)\u003cbr\u003e Rubber base: NBR 80 ±5 Shore\u003c\/p\u003e","brand":"Euchner","offers":[{"title":"Default Title","offer_id":48304755048793,"sku":null,"price":109.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0780\/1434\/9657\/files\/IMG_8610.jpg?v=1715102749"},{"product_id":"ces-a-c5e-01","title":"Euchner CES-A-C5E-01 CES-A safety switch","description":"\u003cp\u003e Safety switch with integrated evaluation electronics; switching of clocked signals possible; 2 safety outputs (semiconductor outputs); Category 3 \/ PL e according to EN ISO 13849-1\u003c\/p\u003e","brand":"Euchner","offers":[{"title":"Default Title","offer_id":48304755081561,"sku":null,"price":139.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0780\/1434\/9657\/files\/IMG_8601.jpg?v=1715103314"},{"product_id":"ces-ar-c01-ah-sa","title":"Euchner CES-AR-C01-AH-SA CES-AR safety switch","description":"\u003cp\u003eSafety switch with integrated evaluation electronics; Up to 20 switches in series; Cross-circuit monitoring; 2 safety outputs (semiconductor outputs); Category 4 \/ PL e according to EN ISO 13849-1; Unicode\u003c\/p\u003e","brand":"Euchner","offers":[{"title":"Default Title","offer_id":48304755114329,"sku":null,"price":159.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0780\/1434\/9657\/files\/IMG_8607.jpg?v=1715108752"},{"product_id":"nz1hs-2131-m","title":"Euchner NZ1HS-2131-M NZ.HS safety switch NZ.HS, swivel lever with steel roller","description":"\u003cp\u003e Electrical connection values:\u003cbr\u003e Connection cross section: 0.34 ... 1.5 mm²\u003cbr\u003e Rated insulation voltage Ui: 250 V\u003cbr\u003e Rated impulse withstand voltage Uimp: 2.5 kV\u003cbr\u003e Usage category:\u003cbr\u003e DC-13: 4A 24V\u003cbr\u003e AC-15: 4A 230V\u003cbr\u003e Short-circuit protection according to IEC 60269-1: 4A gG\u003cbr\u003e Switching current min. at DC 24V: 1 mA\u003cbr\u003e Thermal rated current Ith: 4 A\u003cbr\u003e Mechanical values ​​and environment:\u003cbr\u003e Starting speed: 0.1 ... 60 m\/min\u003cbr\u003e Connection type: 1 x M20 x 1.5\u003cbr\u003e Number of contacts: 1\u003cbr\u003e Number of positive opening door positions: 3\u003cbr\u003e Actuating element: plain bearing metal swivel lever\u003cbr\u003e Operating force min.: 15 N\u003cbr\u003e Installation position: any\u003cbr\u003e Mechanical life: 30 x 10⁶\u003cbr\u003e Switching principle: slow-action switching element\u003cbr\u003e Protection class: IP67\u003cbr\u003e Ambient temperature: -25 ... +80 °C\u003cbr\u003e Material: \u003cbr\u003eHousing: light metal die-cast anodized\u003cbr\u003e Contact: Silver alloy, gold plated\u003c\/p\u003e","brand":"Euchner","offers":[{"title":"Default Title","offer_id":48304755179865,"sku":null,"price":149.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0780\/1434\/9657\/files\/IMG_8605.jpg?v=1715109378"},{"product_id":"nz2rs-511l060","title":"Euchner NZ2RS-511L060 NZ2RS safety position switch","description":"\u003cp\u003e Safety switch NZ.RS, roller plunger, steel roller ø 12 mm, connector SR6;\u003cbr\u003e Display module: AC\/DC, 12 ... 60 ... 60 V LED red;\u003cbr\u003e Rated insulation voltage Ui: 250 V;\u003cbr\u003e Rated impulse withstand voltage Uimp: 2.5 kV;\u003cbr\u003e Usage category: DC-13: 6A 24V AC-15: 6A 230V\u003c\/p\u003e","brand":"Euchner","offers":[{"title":"Default Title","offer_id":48304755212633,"sku":null,"price":49.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0780\/1434\/9657\/files\/IMG_8603.jpg?v=1715109560"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0780\/1434\/9657\/collections\/Euchner.png?v=1699969387","url":"https:\/\/industrialresell.de\/en\/collections\/euchner.oembed","provider":"Industrialresell.de","version":"1.0","type":"link"}